Difference between revisions of "Amcrest"

From ZoneMinder Wiki
Jump to navigationJump to search
(add information on IP2M-723W)
(IP2M-841 is the same as ProHD; merge those sections)
Line 2: Line 2:


=IP2M-841B/IP2M-841W=
=IP2M-841B/IP2M-841W=
[[Image:IP2m-841B.jpg]]
[[Image:IP2m-841B.jpg]]


An indoor IP camera with IR Night vision, this is one of their more prolific models of camera.  
An indoor IP camera with IR Night vision and pan/tilt, this is one of their more prolific models of camera.  
 
==ZoneMinder 1.28-1.30.0==
 
===RTSP===


Tested successfully using:


'''Using RTSP:'''
* ZM 1.28.1, FW 2.420.AC00.11.R


Channel 1: Main Stream = 0, 2nd Stream = 1 (tested successfully using ZM 1.28.1, FW 2.420.AC00.11.R)
  '''General Settings'''
  '''General Settings'''
  Source Type: Ffmpeg
  Source Type: Ffmpeg
Line 20: Line 25:
   rtsp://[username]:[password]@[deviceIP]:554/cam/realmonitor?channel=1&subtype=1
   rtsp://[username]:[password]@[deviceIP]:554/cam/realmonitor?channel=1&subtype=1
  Remote Method: RTP/RTSP
  Remote Method: RTP/RTSP
Capture Width and Height - set to match the stream on the camera


===MJPEG===


Tested successfully using:


'''Using Mjpeg:'''
* ZM 1.28.1, FW 2.420.AC00.11.R


Channel 0: Main Stream = 0, 2nd Stream = 1 (tested successfully using ZM 1.28.1, FW 2.420.AC00.11.R)
  '''Camera Settings'''
  '''Camera Settings'''
  Make sure this stream is enabled on the camera!
  Make sure this stream is enabled on the camera!
Line 38: Line 45:
  Source Path: /cgi-bin/mjpg/video.cgi?channel=0&subtype=1
  Source Path: /cgi-bin/mjpg/video.cgi?channel=0&subtype=1


 
===PTZ Controls===
 
'''PTZ Controls:'''


(Confirmed working, not yet implemented in ZM)
(Confirmed working, not yet implemented in ZM)
Line 56: Line 61:
  Focus-out:/cgi-bin/ptz.cgi?action=start&code=FocusFar&channel=0&arg1=1&arg2=1&arg3=0
  Focus-out:/cgi-bin/ptz.cgi?action=start&code=FocusFar&channel=0&arg1=1&arg2=1&arg3=0
  Stop:/cgi-bin/ptz.cgi?action=stop&code=Right&channel=0&arg1=0&arg2=0&arg3=0&arg4=0
  Stop:/cgi-bin/ptz.cgi?action=stop&code=Right&channel=0&arg1=0&arg2=0&arg3=0&arg4=0
=ProHD:=
General Settings
Source Type: ffmpeg
Source Settings
Source Path:
  For Primary Stream:
  rtsp://user:password@IP_Address:554/cam/realmonitor?channel=1&subtype=0
  For Secondary Stream:
  rtsp://user:password@IP_Address:554/cam/realmonitor?channel=1&subtype=1
Remote Method: RTP/RTSP
Set the resolution (WxH) to match the Stream selected.


=IP2M-723W=
=IP2M-723W=
Line 75: Line 67:


==ZoneMinder 1.30.0==
==ZoneMinder 1.30.0==
Tested successfully using:
* ZM 1.30.0 and firmware "2.400.AC02.15.R, Build Date: 2017-07-31"


  General Settings
  General Settings

Revision as of 07:38, 10 June 2018

Amcrest is a manufacturer of indoor and outdoor IP cameras as well as DVRs.

IP2M-841B/IP2M-841W

IP2m-841B.jpg

An indoor IP camera with IR Night vision and pan/tilt, this is one of their more prolific models of camera.

ZoneMinder 1.28-1.30.0

RTSP

Tested successfully using:

  • ZM 1.28.1, FW 2.420.AC00.11.R
General Settings
Source Type: Ffmpeg

Source Settings
Source Path: 
 For Primary Stream:
 rtsp://[username]:[password]@[deviceIP]:554/cam/realmonitor?channel=1&subtype=0
 For Secondary Stream:
 rtsp://[username]:[password]@[deviceIP]:554/cam/realmonitor?channel=1&subtype=1
Remote Method: RTP/RTSP
Capture Width and Height - set to match the stream on the camera

MJPEG

Tested successfully using:

  • ZM 1.28.1, FW 2.420.AC00.11.R
Camera Settings
Make sure this stream is enabled on the camera!

General Settings
Source Type: Remote

Source Settings
Remote Protocol: HTTP
Remote Method: Simple or Regexp both seem to work
Remote Host Name: [username]:[password]@[deviceIP]
Source Path: /cgi-bin/mjpg/video.cgi?channel=0&subtype=1

PTZ Controls

(Confirmed working, not yet implemented in ZM)

Right:/cgi-bin/ptz.cgi?action=start&code=Right&channel=0&arg1=1&arg2=1&arg3=0
Left:/cgi-bin/ptz.cgi?action=start&code=Left&channel=0&arg1=1&arg2=1&arg3=0
Up:/cgi-bin/ptz.cgi?action=start&code=Up&channel=0&arg1=1&arg2=1&arg3=0
Down:/cgi-bin/ptz.cgi?action=start&code=Down&channel=0&arg1=1&arg2=1&arg3=0
Up-right:/cgi-bin/ptz.cgi?action=start&code=RightUp&channel=0&arg1=1&arg2=1&arg3=0
Up-left:/cgi-bin/ptz.cgi?action=start&code=LeftUp&channel=0&arg1=1&arg2=1&arg3=0
Down-right:/cgi-bin/ptz.cgi?action=start&code=RightDown&channel=0&arg1=1&arg2=1&arg3=0
Down-left:/cgi-bin/ptz.cgi?action=start&code=LeftDown&channel=0&arg1=1&arg2=1&arg3=0
Wide:/cgi-bin/ptz.cgi?action=start&code=ZoomWide&channel=0&arg1=1&arg2=1&arg3=0
Tight:/cgi-bin/ptz.cgi?action=start&code=ZoomTele&channel=0&arg1=1&arg2=1&arg3=0
Focus-in:/cgi-bin/ptz.cgi?action=start&code=FocusNear&channel=0&arg1=1&arg2=1&arg3=0
Focus-out:/cgi-bin/ptz.cgi?action=start&code=FocusFar&channel=0&arg1=1&arg2=1&arg3=0
Stop:/cgi-bin/ptz.cgi?action=stop&code=Right&channel=0&arg1=0&arg2=0&arg3=0&arg4=0

IP2M-723W

A 960P outdoor bullet camera with IR illuminators; available in either wireless (W) or PoE.

ZoneMinder 1.30.0

Tested successfully using:

  • ZM 1.30.0 and firmware "2.400.AC02.15.R, Build Date: 2017-07-31"
General Settings
 SourceType: ffmpeg
Source Settings
 Source Path:
  For Primary Stream: rtsp://user:password@IP_Address:554/cam/realmonitor?channel=1&subtype=0
  For Secondary Stream: rtsp://user:password@IP_Address:554/cam/realmonitor?channel=1&subtype=1
 Remote Method: RTP/RTSP
 Target colorspace: 32 bit
 Capture Width and Height: set to match the stream

ZoneMinder 1.31.44

Unknown