Difference between revisions of "Foscam FI9821W V2"
From ZoneMinder Wiki
Jump to navigationJump to search
(basic formatting) |
(Camera resolution should reflect what has been set into the camera itself) |
||
Line 18: | Line 18: | ||
* Source Path: rtsp://admin:(Password)@IP-Address:88/videoMain | * Source Path: rtsp://admin:(Password)@IP-Address:88/videoMain | ||
* Remote Method: RTP/Unicast | * Remote Method: RTP/Unicast | ||
* Capture | * Capture Resolution (pixels): <code>1280x720 720p</code> preset | ||
* Control Type: Foscam FI9821W (see note 1) | * Control Type: Foscam FI9821W (see note 1) | ||
* Control Device: (Password) (see note 2) | * Control Device: (Password) (see note 2) | ||
Line 33: | Line 32: | ||
Note 2 addendum: I was only able to PTZ working if Control Device was in the format of user:password | Note 2 addendum: I was only able to PTZ working if Control Device was in the format of user:password | ||
You should be able to use higher or lower resolutions but keep the WidthxHeight ratio within the | You should be able to use higher or lower resolutions but keep the WidthxHeight ratio within the values you did set in the Camera settings. |
Revision as of 05:17, 7 March 2020
Foscam FI9821W V2 with control
With the newer version of the Foscam firmware you are prompted to change the default login. I did this then added another user called admin. I'm not sure if this is necessary but I was able to get the camera to work with control.
Camera Video Settings
- Stream Type: HD Mode
- Resolution: 720P
- Bit Rate: 128K
- Frame Rate: 5
- Key Frame Interval: 50
- Variable bitrate: Yes
Zoneminder Monitor Settings
- Source Type: Ffmpeg
- Function: Modect (or your choice)
- Source Path: rtsp://admin:(Password)@IP-Address:88/videoMain
- Remote Method: RTP/Unicast
- Capture Resolution (pixels):
1280x720 720p
preset - Control Type: Foscam FI9821W (see note 1)
- Control Device: (Password) (see note 2)
- Control Address: IP-Address:88
- Auto Stop Timeout: 1
Notes
Note 1: Edit Foscam FI9821W and remove check marks in Zoom, Focus, White, Iris, and change Presets number from 16 to 8
Note 2: You may be able to use just the camera password or user=(user)&pwd=(password)
Note 2 addendum: I was only able to PTZ working if Control Device was in the format of user:password
You should be able to use higher or lower resolutions but keep the WidthxHeight ratio within the values you did set in the Camera settings.