Foscam FI9821W V2 with control
With the newer version of the Foscam firmware you are prompted to change the default login. I did this then added another user called admin. I'm not sure if this is necessary but I was able to get the camera to work with control.
Camera Video Settings: Stream Type HD Mode Resolution 720P Bit Rate 128K Frame Rate 5 Key Frame Interval 50 Variable bitrate Yes
Zoneminder Monitor Settings: Source Type Ffmpeg Function Modect (or your choice) Source Path rtsp://admin:(Password)@IP-Address:88/videoMain Remote Method RTP/Unicast Capture Width 640 Capture Height 320 Control Type Foscam FI9821W (see note 1) Control Device (Password) (see note 2) Control Address IP-Address:88 Auto Stop Timeout 1
Note 1: Edit Foscam FI9821W and remove check marks in Zoom, Focus, White, Iris, and change Presets number from 16 to 8
Note 2: You may be able to use just the camera password or user=(user)&pwd=(password)