Hikvision
These seem to work. The biggest problem is people trying to use 'network camera' instead of 'ffmpeg' source type. Both have rtsp but only ffmpeg works here (because of h.264?) see [[1]]
The DS-2CD2632F-IS Update Version outdoor bullet works with ZM 1.30.4 ONVIF works for fast setup. See Model Specific Wiki page Hikvision DS-2CD1631FWD-I CCTV POE 3MP HD Varifocal IR Bullet
The DS-2CD2732F-I and DS-2CD2032-I are tested.
[The DS-2CD2032-I's come in several different versions (Chinese, Int'l, English, etc...) each with multiple firmwares available. Be sure that you use the correct firmware for your camera model for best results.]
The DS-2CD2035-I outdoor bullet works using Ffmpeg.
The DS-2CD2532F-IWS was tested to work reliably only with Libvlc as source type.
The DS-2CD2012-I works too.
Videostream:
General Tab
- Source Type : Ffmpeg / Libvlc / Remote(only some FW revisions)
Source Tab
- Source Path : rtsp://<username>:<password>@<ip_address>:<port>/Streaming/Channels/1?tcp
(example: rtsp://admin:12345@mycamera.mydomain.com//Streaming/Channels/1)
- Target Colorspace : 24 bit colour
- Capture Width (pixels) : 1280 (set these to match camera config)
- Capture Height (pixels) : 720
I also had to set max FPS slightly higher than set in camera, or i lost the lower half of the frame. (Camera seems to send 10.6fps when 10 is selected)
The following URL gives another Source path that was far more stable on Zoneminder 1.25: http://onlinetechadvice.blogspot.com/2014/04/hikvision-ds-2cd2032-i-working-in.html#comment-form
The Source path that worked for me is: rtsp://username:password@XXX.XXX.XXX.XXX:554/cam/realmonitor?channel=1&subtype=0?tcp Of course, replace username and password and port with your specific installation information.
The "Remote" option also seems to work now in ZM 1.28 (at least with ds-2cd2032-i's of a certain firmware version), with less rtsp streaming errors than when using ffmpeg. The source path /Streaming/Channels/1 works fine with firmware version 5.1.6, but seems to not work any longer in 5.2.5. The source path /cam/realmonitor?channel=1&subtype=0 works on any firmware model. In ZM 1.28 (perhaps earlier as well), TCP is automatically forced when the "Remote" source type is chosen and RTP/RTSP is used (https://github.com/ZoneMinder/ZoneMinder/issues/323), so the trailing "?tcp" is not necessary for either URL when this configuration is used.
Model specific wikis
Hikvision DS-2CD1631FWD-I CCTV POE 3MP HD Varifocal IR Bullet
Hikvision DS-2CD2732F-I(S) Megapixel Outdoor IP Dome Camera
Hikvision DS-2CD2532F-IWS 3MP Outdoor IP Mini Dome Camera
Hikvision DS-2CD2012-I 1.3MP IR Mini Bullet Camera
Hikvision DS-2CD2332-I 3MP Outdoor Network Mini Dome Camera
For the DS-2CD2032-I model, see the line above (the DS-2CD2332-I model).
Hikvision_DS-2CD2142FWD-I 4MP Mini Vandal Dome IP Camera PoE