Foscam FI9821W V2
From ZoneMinder Wiki
Jump to navigationJump to search
Foscam FI9821W V2 with control
With the newer version of the Foscam firmware you are prompted to change the default login. I did this then added another user called admin. I'm not sure if this is necessary but I was able to get the camera to work with control.
Camera Video Settings
- Stream Type: HD Mode
- Resolution: 720P
- Bit Rate: 128K
- Frame Rate: 5
- Key Frame Interval: 50
- Variable bitrate: Yes
Zoneminder Monitor Settings
- Source Type: Ffmpeg
- Function: Modect (or your choice)
- Source Path: rtsp://admin:(Password)@IP-Address:88/videoMain
- Remote Method: RTP/Unicast
- Capture Width: 640
- Capture Height: 320
- Control Type: Foscam FI9821W (see note 1)
- Control Device: (Password) (see note 2)
- Control Address: IP-Address:88
- Auto Stop Timeout: 1
Notes
Note 1: Edit Foscam FI9821W and remove check marks in Zoom, Focus, White, Iris, and change Presets number from 16 to 8
Note 2: You may be able to use just the camera password or user=(user)&pwd=(password)
Note 2 addendum: I was only able to PTZ working if Control Device was in the format of user:password
You should be able to use higher or lower resolutions but keep the WidthxHeight ratio within the 640x320 value