Difference between revisions of "Airlink 101"

From ZoneMinder Wiki
Jump to navigationJump to search
 
(One intermediate revision by the same user not shown)
Line 81: Line 81:
Remote Image colors: 24 bit
Remote Image colors: 24 bit


Capture Width: 640
Capture Width: 320


Capture Height: 480
Capture Height: 240
 
you also have to change a setting in the camera setup>video>mpeg4>QVGA and setup>video>mjpeg>QVGA
 
For Zoneminder this will work but I wouldnt recommend. There is a very long lag time before the camera sees an image and it is shown on Zoneminder. It has taken up too 1 minute before i have seen change in the camera feed.

Latest revision as of 13:31, 27 January 2012

AIC250W

Airlink101 AIC250 settings for 2 fps as JPG stream: to use this camera with Zoneminder with JPG stream, use these settings for the Monitor: "hostname = <ip of camera>", "path = /image.jpg", use these settings for Options: "ffmpeg" as encoder, "jpg" stream and not mpeg. Select the right resolution for the camera, such as 640x480. To set the resolution for the camera, use a web browser and go to the configuration pages http://<ip of camera>. While in the configuration pages, delete the username and password to get the camera to work with these settings. Save the camera configuration.

AIC250W - Just remember to turn off PCRE processing in the Options > Network tab. http://x.x.x.x/video.cgi gives 10 fps 640 x 480 mjpeg feed. Same camera as D-Link DCS-900W / TrendNet IP-200

AICN747/AICN747W (Airlink101 SkyIPCam 747W)

Same Camera as Fitivision CS-130A/CS-131A and TrendNet TV-IP410/TV-IP410W. The 'W'/CS-131A version is wireless. Note: the Trendnet cameras have no built-in IR illumination.

The device requires authentication, so you need to provide the Remote Host Name parameter with hostname = <username>:<password>@<ip of camera> path = /cgi/jpg/image.cgi for JPEG stills, or /cgi/mjpg/mjpg.cgi for MJPEG (MJPEG mode requires firmware v1.0.0-24 or later)


Remote Protocol: HTTP

Remote Method: Simple

Remote Host Name: <username>:<password>@<ip of camera>

Remote Host Port: 80

Remote Host Path: /cgi/mjpg/mjpg.cgi

Remote Image colors: 24 bit

Capture Width: 640

Capture Height: 480


Airlink Skyipcam777w

Remote Protocol: HTTP

Remote Method: Simple

Remote Host Name: {username}:{password}@{camera ip}

Remote Host Port: 80

Remote Host Path: /cgi/mjpg/mjpg.cgi

Remote Image colors: 24 bit

Capture Width: 640

Capture Height: 480



AICN1620W

JPEG stills <IP_ADDRESS>/cgi/jpg/image.cgi

MJPEG <IP_ADDRESS>/cgi/mjpg/mjpg.cgi


Remote Protocol: HTTP

Remote Method: Simple

Remote Host Name: <username>:<password>@<ip of camera>

Remote Host Port: 80

Remote Host Path: /cgi/mjpg/mjpg.cgi

Remote Image colors: 24 bit

Capture Width: 320

Capture Height: 240

you also have to change a setting in the camera setup>video>mpeg4>QVGA and setup>video>mjpeg>QVGA

For Zoneminder this will work but I wouldnt recommend. There is a very long lag time before the camera sees an image and it is shown on Zoneminder. It has taken up too 1 minute before i have seen change in the camera feed.