Airlink 101

From ZoneMinder Wiki
Revision as of 02:04, 19 September 2008 by Setarcos (talk | contribs) (Added link to PTZ module for AICN747 and made a few formatting changes)
Jump to navigationJump to search

AIC250W

Airlink101 AIC250 settings for 2 fps as JPG stream: to use this camera with Zoneminder with JPG stream, use these settings for the Monitor: "hostname = <ip of camera>", "path = /video.jpg", use these settings for Options: "ffmpeg" as encoder, "jpg" stream and not mpeg. Select the right resolution for the camera, such as 640x480. To set the resolution for the camera, use a web browser and go to the configuration pages http://<ip of camera>. While in the configuration pages, delete the username and password to get the camera to work with these settings. Save the camera configuration.

AIC250W - Just remember to turn off PCRE processing in the Options > Network tab. http://x.x.x.x/video.cgi gives 10 fps 640 x 480 mjpeg feed. Same camera as D-Link DCS-900W / TrendNet IP-200


AICN747/AICN747W

Same Camera as Fitivision CS-130A/CS-131A and TrendNet TV-IP410/TV-IP410W. The 'W'/CS-131A version is wireless. Note: the Trendnet cameras have no built-in IR illumination.

hostname = <username>:<password>@<ip of camera> path = /cgi/jpg/image.cgi for JPEG stills, or /cgi/mjpg/mjpeg.cgi for MJPEG (MJPEG mode doesn't return the correct MIME type, and thus doesn't appear to work with ZM)

PTZ module details: SkyIPCam 7xx ZM Module and Audio dump script

Additional info on the AirLink SkyIPCam 747W