Difference between revisions of "How to Setup a FLIR F-Series Thermal Camera with MPEG4 streaming"
From ZoneMinder Wiki
Jump to navigationJump to search
m |
|||
Line 11: | Line 11: | ||
# Access the camera web interface | # Access the camera web interface | ||
# Open the Video IR configuration and configure using the following settings: | # Open the Video IR configuration and configure using the following settings: | ||
* Enabled: Yes | |||
* Associated uFLIRish Id: 0 | |||
* Channel Id: 0 | |||
* Video Source: Type: IR | ID: 0 | |||
* Format: PAL | |||
* Interface: .... | |||
* Port: 554 | |||
* RTP/RTSP over HTTP Port: 8080 | |||
* Stream Name: ch0 | |||
* Use External IP: no | |||
* Enable Multicast: no | |||
* Codec Type: MPEG4 | |||
* Bit Rate: 3000000 | |||
* Rate Control: CBR | |||
* I-Frame Interval: 30 | |||
* Image Size: D1 | |||
* Frame Rate: 10 | |||
* Interlaced: no | |||
<br/> | <br/> | ||
==Zone Minder configuration== | ==Zone Minder configuration== | ||
Line 34: | Line 34: | ||
# Click on the "Add New Monitor" link located at the bottom of the page, this will take you to the configuration page for adding a new camera. | # Click on the "Add New Monitor" link located at the bottom of the page, this will take you to the configuration page for adding a new camera. | ||
# General Tab - Use the following settings: | # General Tab - Use the following settings: | ||
* Name of the monitor | |||
* Source Type - Remote | |||
* Function - Modetect | |||
# Source Tab - Use the following settings: | # Source Tab - Use the following settings: | ||
* Remote Protocol - RTSP | |||
* Remote Method - RTP/Unicast | |||
* Remote Host Name - <ip-address> | |||
* Remote Host Port - 554 | |||
* Remote Host Path - /ch0 | |||
* Remote Image Colours - 24 bit colour | |||
* Capture Width (pixels) - 720 | |||
* Capture Height (pixels) - 576 | |||
* Preserve aspect ratio - OFF | |||
* Orientation - Normal | |||
==Monitor Resolution== | ==Monitor Resolution== | ||
The resolution can be changed, some of the available resolutions: | The resolution can be changed, some of the available resolutions: | ||
* QCIF 176x144 | |||
* 4CIF 704x576 | |||
* D1 720x576 |
Revision as of 13:15, 7 November 2011
Go back to the How To pages...
Prerequisites
- IP address of camera.
- Username and password for the camera.
- Administrator access to Zone Minder.
Checking camera configuration
- Access the camera web interface
- Open the Video IR configuration and configure using the following settings:
- Enabled: Yes
- Associated uFLIRish Id: 0
- Channel Id: 0
- Video Source: Type: IR | ID: 0
- Format: PAL
- Interface: ....
- Port: 554
- RTP/RTSP over HTTP Port: 8080
- Stream Name: ch0
- Use External IP: no
- Enable Multicast: no
- Codec Type: MPEG4
- Bit Rate: 3000000
- Rate Control: CBR
- I-Frame Interval: 30
- Image Size: D1
- Frame Rate: 10
- Interlaced: no
Zone Minder configuration
- Login to Zone Minder.
- Click on the "Add New Monitor" link located at the bottom of the page, this will take you to the configuration page for adding a new camera.
- General Tab - Use the following settings:
- Name of the monitor
- Source Type - Remote
- Function - Modetect
- Source Tab - Use the following settings:
- Remote Protocol - RTSP
- Remote Method - RTP/Unicast
- Remote Host Name - <ip-address>
- Remote Host Port - 554
- Remote Host Path - /ch0
- Remote Image Colours - 24 bit colour
- Capture Width (pixels) - 720
- Capture Height (pixels) - 576
- Preserve aspect ratio - OFF
- Orientation - Normal
Monitor Resolution
The resolution can be changed, some of the available resolutions:
- QCIF 176x144
- 4CIF 704x576
- D1 720x576